Storage reinvented to unlock innovation and agility

XtremIO X2

Purpose-built, all-flash storage array delivers always-on, flash-optimized data services

Close

Dell EMC XtremIO X2 All-Flash Array

Performance and Efficiency

  • Predictable and consistent high performance with low submillisecond latency
  • 4 to 20 times data reduction using inline deduplication and compression, XtremIO Virtual Copies, and thin provisioning
  • Consumer simplicity with enterprise capabilities
  • Ease of use—nothing to configure or tune

Applications

  • Exceed the toughest SLAs for virtualized workloads
  • Enable near real-time copies of production datasets

Business

  • Enables unique copy data management capabilities to unlock business agility through improved workflows
  • Reduces costs by one third and provides smaller, incremental scaling options
  • Provides two times longer storage product lifecycles than traditional arrays
  • Delivers business continuity with WAN efficient metadata-aware native replication

Tech Specs
Feature Description
Typical effective capacity with data reduction Up to 5.5 PBe (petabytes of effective capacity)
Storage type SAN
Drive type SSD
Max number of SSDs 72 per X-Brick
Dell EMC XtremIO X2 XIOS v6.0.2 or higher1 Brick Cluster2 Bricks Cluster3 Bricks Cluster4 Bricks Cluster
System Specifications

Active-Active Controllers

2

4

6

8

SSD enclosures

1

2

3

4

Number of SSDs

18-72*

36-144

54-216

72-288

Cable management ducts (CMD)**

1

1

2

2

Infiniband Switches

0

2

2

2

Power Socket Number/Type (internal to rack)

6 x IEC C14

16 x IEC C14

22 x IEC C14

28 x IEC C14

Weight*** (including rack)

293Kg/646lb

400Kg/882lb

490Kg/1080lb

580Kg/1278lb

Weight*** (excluding rack)

95Kg/209lb

202Kg/445lb

292Kg/644lb

382Kg/842lb

Rack Space (including CMD)

5U

11U

16U

20U

Performance (100% random IOs, no caching, on preconditioned & prefilled arrays)

IOPS 70% read, 30% write (8K blocks)

220,000

440,000

660,000

880,000

Average Latency (ms)

0.5

0.5

0.5

0.5

Max. Bandwidth (GB/s)

6

12

18

24

Host Connectivity (Default/iSCSI only config****)

Fibre Channel Ports (16Gbps)

4

8

12

16

iSCSI Ethernet Ports (10Gbps)

4 to 8

8 to 16

12 to 24

16 to 32

Management

Management Ethernet Ports (10Gbps)

2

2

2

2

Management IP Addresses Required

2+1 (XMS)

2+1 (XMS)

2+1 (XMS)

2+1 (XMS)

XMS Management Server

A single XMS (physical server or VM) manages multiple XtremIO arrays, requires IP address

A single XMS (physical server or VM) manages multiple XtremIO arrays, requires IP address

A single XMS (physical server or VM) manages multiple XtremIO arrays, requires IP address

A single XMS (physical server or VM) manages multiple XtremIO arrays, requires IP address

X2-R

Raw Capacity

TB: 34.6-138.2
TiB: 31.4-125.7

TB: 69.1-276.5
TiB: 62.9-251.5

TB: 103.7-414.7
TiB: 94.3-377.2

TB: 138.2-553
TiB: 125.7-502.9

Usable Capacity*****

TB: 27-123
TiB: 25-112

TB: 55-246
TiB: 50-224

TB: 83-369
TiB: 76-336

TB: 111-493
TiB: 101-448

Effective Capacity****** (TB)

738

1476

2214

2958

Power Consumption (steady state) (VA)

1400-1700

3000-3510

4420-5200

5850-6900

Cooling Requirements (BTU/hr)

4,800-5,800

10,240-12,000

15,090-17,750

20,000-23,550

X2-S

Raw Capacity

TB: 7.2-28.8
TiB: 6.55-26.2

TB: 14.4-57.6
TiB: 13.1-52.4

TB: 21.6-86.4
TiB: 19.7-78.6

TB: 28.8-115.2
TiB: 26.2-104.8

Usable Capacity*****

TB: 5.4-24
TiB: 4.9-22

TB: 11-49
TiB: 10-45

TB: 16-74
TiB: 15-67

TB:21-99
TiB: 20-90

Effective Capacity****** (TB)

132

271

406

543

Power Consumption (steady state) (VA)

1300-1580

2890-3410

4200-5000

5510-6550

Cooling Requirements (BTU/hr)

4,440-5,400

9,870-11,640

14,340-17,070

18,810-22,360

X2-T Single Brick

Raw Capacity

TB: 34.6-69.1
TiB: 31.4-62.9

Usable Capacity*****

TB: 27-61.5
TiB: 25-56

Effective Capacity****** (TB)

369

Power Consumption (steady state) (VA)

1400-1550

Cooling Requirements (BTU/hr)

4,800-5,300

*X2-T can support up to 36 SDDs.
**Cable Management Duct optional.
***These are X2-R values. For X2-S multi-brick weight subtract 8.5Kg (single bricks weigh the same).
****Cluster can be configured to have only iSCSI connections and no FC connections.
*****Usable capacity is the amount of unique, non-compressible data that can be written into the array.
******Effective capacity includes the benefits of thin provisioning, inline global deduplication, inline compression, and spaceefficient copies. Datasheet numbers are a representative example at 6:1 and will vary based on each customer’s specific application environment and use of the XtremIO array.
Close
OK

Cookies on our site: We use cookies to provide you with the best experience on our site. Use of this website signals your consent to use cookies. Learn more about cookies