New entry point to advanced SC Series features

SCv3000, SCv3020 all-in-one arrays

Our most affordable hybrid array now offers unprecedented enterprise-class capabilities

Close

SCv3000 all-in-one array

  • Data Progression — Auto-tunes your environment for maximum performance and cost savings based on real-time usage information
  • 0 – 100% Flash Architecture — Set any mix of SSDs and HDDs to match your price/performance goals, then modify that mix as your needs change
  • Intelligent Compression — Reduce capacity costs for both SSDs and HDDs, even on auto-tiered volumes in hybrid configurations
  • SC Series Replication – Replicate with SC4020, SC5020, SC7020 and SC9000 arrays
  • SC Series Federation – Simplify heterogenous multi-array environments with quick and seamless load balancing that preserves host mappings, snapshots and replication status
  • Low-cost Business Continuity — Keep mission-critical apps running during unexpected outages and disasters with volume-level auto-failover between local and remote arrays
  • Customer Installable — With ProDeploy, ProSupport and new Optimize services options

Tech Specs Fast Facts
Feature Description
Processors Intel® Xeon® Processor E5-2603v4, 1.7GHz, 6 cores
Controllers 2 hot-swappable per chassis (active/active)
Operating system Dell Storage Center OS (SCOS) 7.2.11 or greater
Max system memory 32GB per array (64GB per controller)
Internal storage capacity 16 x 3.5” drive bays
Max drive count 222 (using optional expansion enclosures)
Max raw capacity 1PB per array (SSD or HDD)

SCv3000 Series

> 500,000 max IOPS with latency under 1ms

Based on internal tests performed in February, 2018 on all-flash configurations. 100% sequential reads with 4K sector transfer size. Actual performance will vary based on configuration, usage and manufacturing variability.

> 230,000 IOPS for 80/20 OLTP-type workloads

Based on internal tests performed in February 2018 on all-flash configurations running OLTP type workloads with 80% reads, 20% writes and 4k sector transfer size. Actual performance will vary based on configuration, usage and manufacturing variability.

19,000 MB/s bandwidth

Based on internal tests in February 2018 on all-flash configurations running 100% sequential reads. Tests covered 256Kb-2048Kb sector transfer sizes. Actual performance will vary based on model, configuration, usage and manufacturing variability.
Close
SC HybridSCv3000 Series
Chassis Overview

Rack size

3U

Format

All-in-one unit (dual controllers, internal drive bays, network I/O)
Additional capacity via optional expansion enclosures

Internal storage capacity

30 x 2.5" drive bays

Controllers

Dual hot-swappable per chassis (active/active)

Processors

1 per controller
Intel® Xeon ® E5-2603v4, 1.7GHz, 6 cores

System memory

Operating system

SCOS 7.2 or higher

Expansion Capacity

Max raw capacity

1PB

Maximum drive count

222

Supported expansion enclosures

12Gb SAS
SCv300: 12 x 3.5" bays SCv320: 24 x 2.5" bays
SCv360: 60 x 3.5" bays

Storage media support

SAS, NL-SAS (different drive types, transfer rates and rotational speeds can be mixed in same system)
SSD: Write-intensive and read-intensive drives
HDD: 15K, 10K, 7.2K RPM

Network and Expansion I/O

Front-end-network protocols

FC, iSCSI (supports simultaneous multiprotocol)

Max 32Gb FC ports

NA

Max 16Gb FC ports

8 per array (SFP+)

Max 100Gb iSCSI ports(9)

NA

Max 25Gb iSCSI ports(9)

NA

Max 10Gb iSCSI ports

16 per array
(SFP+ or BASE-T)

Max 12Gb SAS (front-end)

8 per array

Management ports

2 per array (1Gb BASE-T)

Back-end expansion protocols

12Gb SAS

Max back-end expansion ports

8

Functional & Performance

Array configurations

All-flash, all-HDD, or hybrid mix

Storage format

Native block (SAN)(15)

Max SAN hosts

250

Max initiator ports

500

Max LUN size

500TB

Max number of LUNs

1000

Max number of snapshots

4096

Max IOPS(2)

665000

Max IOPS(2)
(with latency <1ms)

540000

Max IOPS(9)
(80% reads, 20% writes)

231000

Max throughput (reads)(11)

19,000 MB/s

Max throughput (writes)(11)

9,500 MB/s

Data Optimization

Auto-tiering method

Policy-based migration based on real-time data usage, customizable 512KB-4MB page size.

Auto-tiering structure

Up to 3 primary (media-based) tiers total, up to 2 SSD tiers (write- and read-intensive SSDs)

RAID tiering

Auto-provisions and dynamically restripes multiple RAID levels on the same tier; eliminates need to pre-allocate RAID groups

Tiering customizations

User-defined profiles, option to "pin" volumes to any tier or RAID level

RAID support

RAID 0, 1, 5, 6, RAID 10, and RAID 10 DM (Dual Mirror); any combination of RAID levels can exist in single array

Thin provisioning

Active by default on all volumes, operates at full performance across all features

Thin snapshots

Records changes only, snapshots auto-migrate to lower-cost storage

Intelligent deduplication and compression

Compression only, selectable option per volume

Data Mobility and Migration Replication

Heterogeneous arrays (SC Series any-to-any)
Synchronous/Asynchronous via FC or iSCSI
Target/source relationships may be one-to-many or many-to-one
Supports all SC data services on source and target volumes
Change replication types and topologies on demand
Supports cross-platform replication with PS Series/EqualLogic arrays (either direction)

Volume mobility

Live Migrate (included in base product) enables host-transparent data movement among arrays; see also Federation section

Federated multi-array systems

Live Migrate (included in base product) enables host-transparent movement of volumes among arrays
Snapshots maintained/preserved during migration(14)

Thin Import

Space-efficient, non-disruptive data migration from PS Series (EqualLogic) and MD3 arrays

Thin Clones

Clone standalone volumes with zero duplication of data
Clones maintain independent snapshots and replication
Ideal for VDI, test/dev, other applications that require discrete instances of common data
More efficient than dedupe for database copies

Data Protection, Disaster Recovery, Security, Business continuity

Live Volume bi-directional auto-failover, auto-repair3
Heterogeneous arrays (SC Series any-to-any, except SCv2000)
Continuous operations, disaster recovery, disaster avoidance
Includes third-site (tertiary) replication options with Live Volume Managed Replication
Zero RTO/RPO with customizable site failover SLAs per volume
VMware Metro Stretch Cluster, VMware Site Recovery Manager support

Thin snapshots

Records changes only, snapshots auto-migrate to lower-cost storage

Replay Manager

Application-consistent snapshots in Microsoft, VMware, Oracle environments

Data-at-rest encryption

Supports self-encrypting drives (SEDs)
Full Disk Encryption (FCE) based on AES-256
Drives certified to FIPS 140-2 Level 2
Key Management Server (KMS) options available for FIPS 140-2 Level 1, 2 and 3

External key manager support

Gemalto's SafeNet KeySecure k460, SafeNet KeySecure k250, SafeNet KeySecure k150v
Thales EMS 200

Management

Management interface

Browser-based (HTML 5)
- CloudIQ (cloud-based storage monitoring and analytics)
- Unisphere for SC (single-array element manager, no software installation required)
- Unisphere Central for SC (multi-array management)

Client application
- Dell Storage Manager Advanced multi-array, multi-site and cross-platform (PS Series) management

Federation

Create large multi-array systems under unified management, with seamless workload migration between arrays via included Live Migrate feature. Add arrays non-disruptively, efficiently utilizing their combined capacity and performance. Volume Advisor monitors federated arrays to suggest optimal data placement and load balancing. Volume movement does not impact snapshots or replication data protection. Federate like or unlike arrays, all SC models supported.(13)

Scripting support

Microsoft PowerShell API
RESTful API

Host OS support

Microsoft® Windows Server®, SLES, VMware®, Citrix® XenServer®, RedHat®

Third-party application integration

VMware, Microsoft, IBM, OpenStack, Symantec, CommVault, Foglight, Docker

Data-in-place upgrades

NA

Coexistence with PS Series arrays

Replication in either direction
Day-to-day management from a single interface
Thin import: space-efficient, non-disruptive data migration from PS Series arrays

Certifications

VMware vSphere Metro Storage Cluster, VMware SRM, Veritas Storage Foundations Suite, IBM VIOS Recognized, Oracle Validated Infrastructure (OVI); see Dell Storage Support Matrix for additional certifications and details

Reporting/alerts

Support assist (phone home), remote diagnostics and performance monitoring, automated alerts, reports and notifications, departmental chargeback

Firmware upgrade

Online, non-disruptive(16). Firmware may be set to download automatically, with option to trigger installation manually if desired.

Workload management

QoS, VVOLs

Physical

Rack size

3U

Height

13.33 cm (5.25 inches)

Width

44.5 cm (17.52 inches)

Depth

78.5 cm (30.9 inches)

Weight at max configuration

24.22 kg (53.4 lb)

Weight empty

15.15 kg (33.4 lb)

Rack support

ReadyRails™ II static rails for tool-less mounting in 4-post racks with square or unthreaded round holes, or tooled mounting in 4-post threaded-hole racks

Power

Power/wattage

2 hot-swappable power supplies (1378W or 1485W options)

Maximum output power

1378W supply option: 1378 W
1485W supply option: 1485 W

Maximum input power

1378W supply option: 1584 W
1485W supply option: 1688 W

Maximum input current

1378W supply option: 16 A
1485W supply option: 8.8 A

Maximum inrush current

55A for 10 ms or less

Nominal input voltage operating range

1378W supply option: 100-240 VAC
1485W supply option: 200-240 VAC

Nominal input frequency

50/60 Hz

Thermal output/heat dissipation (maximum)

1378W option: 5,770 BTU per hour
1485 option: 5,760 BTU per hour
(all-in-one base appliance, no expansion enclosures)

Environmental Operating Conditions

Operating temperature

50 - 95°F (10 - 35°C)

Non-operating temperature

-40 - 149°F (-40 - 65°C)

Operating humidity ranges (non-condensing)

10% to 80% with 29°C (84.2°F) maximum dew point

Non-operating humidity (non-condensing)

5% to 95% with 33°C (91°F) maximum dew point

Inlet type

NEMA 5-15/CS22.2, n°42

Services, Warranties(7)

Services

Dell ProSupport with deployment and consulting services. Optional ProSupport Plus is available offering proactive and preventative services to improve performance and stability. Dell Optimize is available for additional ongoing strategic counsel and guidance from a highly trained system analyst.

Diagnostics engine

Integrated Dell Remote Access Controller (iDRAC)

System sizing

Dell EMC Live Optics

Drive warranty

All SSDs are warrantied for full lifetime wear-out replacement with valid service agreement. SSD warranty covers all formats: SLC, MLC and TLC

(1) Net usable capacity of Dell array with 5 years of support, after 4:1 data reduction, vs. major competitors net of data reduction. Street price analysis is based on a variety of sources including analyst data, price sheets when available, and public information as of January 2017.

(2) Based on internal tests performed in February, 2018 on all-flash configurations. 100% sequential reads with 4K sector transfer size. Actual performance will vary based on configuration, usage and manufacturing variability. See Specifications section for additional Dell EMC performance test results.

(3) Requires optional Live Volume feature

(4) Based on internal tests in February 2018 on all-flash SC9000 configurations running 100% sequential reads. Tests covered 16Kb-2048Kb sector transfer sizes. Actual performance will vary based on model, configuration, usage and manufacturing variability.

(5) Based on internal tests performed by Dell EMC on SCv3000 array with and without distributed sparing mode active. Actual performance will vary based on configuration, usage and manufacturing variability.

(6) Ranking by vendor revenue. IDC Tracker, "Worldwide Quarterly Enterprise Storage Systems Tracker." 1Q17.

(7) Availability and terms of Dell Services vary by region. Contact your Dell representative or Authorized Partner for details.

(8) Contact your Dell EMC representative or Authorized Partner for details regarding the Future-Proof Storage Loyalty Program. Terms and Conditions apply.

(9) Requires update to SCOS 7.3 for support. Subject to hardware availability (estimated Q218 for 25Gb, Q318 for 100Gb).

(10) Based on internal tests performed in February 2018 on all-flash configurations running OLTP type workloads with 80% reads, 20% writes and 4k sector transfer size. Actual performance will vary based on configuration, usage and manufacturing variability.

(11) Based on internal tests in February 2018 on all-flash configurations running 100% sequential reads. Tests covered 16Kb-2048Kb sector transfer sizes for SC9000, and 256Kb-2048Kb sizes for SCv3000, SC5020 and SC7020. Actual performance will vary based on model, configuration, usage and manufacturing variability.

(12) Based on internal tests in February 2018 on all-flash configurations running 100% sequential writes. Tests covered 64Kb-2048Kb sector transfer size for SC9000 and SC5020, 128Kb-2048Kb for SC7020, and 256Kb-2048Kb for SC7020. Actual performance will vary based on model, configuration, usage and manufacturing variability.

(13) Multiple SC Series arrays may be deployed in federated configurations using the Live Migrate feature included with firmware version 7.1 and above. Transparent, non-disruptive volume movement among arrays is enabled, allowing the combined capacity and cache of the entire federated cluster to be seamlessly utilized for maximum performance and scalability in expanding data centers. For example, a cluster of 10 SC9000 arrays can provide a total of over 10,000 drives (up to 60PB raw capacity) with over 5TB of system memory.

(14) Available Q218 for SC5020, Q318 for SC7020. Professional Services assistance required, subject to system eligibility requirements. Contact your Dell EMC representative or Authorized Partner for details.

(15) File solution available via optional NX Series NAS appliance.

(16) Although upgrades are non-disruptive in the vast majority of cases, Dell EMC reserves the right to release firmware that requires a reboot if necessary to protect user security or system integrity.
Close
Close

SCv3020 all-in-one array

  • Data Progression — Auto-tunes your environment for maximum performance and cost savings based on real-time usage information
  • 0 – 100% Flash Architecture — Set any mix of SSDs and HDDs to match your price/performance goals, then modify that mix as your needs change
  • Intelligent Compression — Reduce capacity costs for both SSDs and HDDs, even on auto-tiered volumes in hybrid configurations
  • SC Series Replication – Replicate with SC4020, SC5020, SC7020 and SC9000 arrays
  • SC Series Federation – Simplify heterogenous multi-array environments with quick and seamless load balancing that preserves host mappings, snapshots and replication status
  • Low-cost Business Continuity — Keep mission-critical apps running during unexpected outages and disasters with volume-level auto-failover between local and remote arrays
  • Customer Installable — With ProDeploy, ProSupport and new Optimize services options
Tech Specs Fast Facts
Feature Description
Processors Intel® Xeon® Processor E5-2603v4, 1.7GHz, 6 cores
Controllers 2 hot-swappable per chassis (active/active)
Operating system Dell Storage Center OS (SCOS) 7.2.11 or greater
Max system memory 32GB per array (64GB per controller)
Internal storage capacity 30 x 2.5” drive bays
Max drive count 222 (using optional expansion enclosures)
Max raw capacity 1PB per array (SSD or HDD)

SCv3000 Series

>270,000 max IOPS

Based on internal tests performed by Dell in June, 2017.  100% sequential reads with 8K sector transfer size.  Actual performance will vary based on configuration and usage and manufacturing variability.

>120,000 IOPS for 70/30 OLTP-type  workloads

Internal test performed by Dell in June, 2017 running OLTP type workloads with 70% reads, 30% writes and 8k sector transfer size. Actual performance will vary based on configuration, usage and manufacturing variability.

>19,000 MB/s bandwidth

Based on internal tests performed by Dell in June, 2017.  100% sequential reads with 256K sector transfer size.  Actual performance will vary based on configuration and usage and manufacturing variability.
Close
SC HybridSCv3000 Series
Chassis Overview

Rack size

3U

Format

All-in-one unit (dual controllers, internal drive bays, network I/O)
Additional capacity via optional expansion enclosures

Internal storage capacity

30 x 2.5" drive bays

Controllers

Dual hot-swappable per chassis (active/active)

Processors

1 per controller
Intel® Xeon ® E5-2603v4, 1.7GHz, 6 cores

System memory

Operating system

SCOS 7.2 or higher

Expansion Capacity

Max raw capacity

1PB

Maximum drive count

22

Supported expansion enclosures

12Gb SAS
SCv300: 12 x 3.5" bays SCv320: 24 x 2.5" bays
SCv360: 60 x 3.5" bays

Storage media support

SAS, NL-SAS (different drive types, transfer rates and rotational speeds can be mixed in same system)
SSD: Write-intensive and read-intensive drives
HDD: 15K, 10K, 7.2K RPM

Network and Expansion I/O

Front-end-network protocols

FC, iSCSI (supports simultaneous multiprotocol)

Max 32Gb FC ports

NA

Max 16Gb FC ports

8 per array (SFP+)

Max 100Gb iSCSI ports*********

NA

Max 25Gb iSCSI ports*********

NA

Max 10Gb iSCSI ports

16 per array
(SFP+ or BASE-T)

Max 12Gb SAS (front-end)

8 per array

Management ports

2 per array (1Gb BASE-T)

Back-end expansion protocols

12Gb SAS

Max back-end expansion ports

8

Functional & Performance

Array configurations

All-flash, all-HDD, or hybrid mix

Storage format

Native block (SAN), file (NAS) from same pool with optional FS8600

Max SAN hosts

250

Max initiator ports

500

Max LUN size

500TB

Max number of LUNs

1000

Max number of snapshots

4096

Max IOPS**

665000

Max IOPS**
(with latency <1ms)

540000

Max IOPS*********
(80% reads, 20% writes)

231000

Max throughput (reads)***********

19,000 MB/s

Max throughput (writes)***********

9,500 MB/s

Data Optimization

Auto-tiering method¾

Policy-based migration based on real-time data usage, customizable 512KB-4MB page size.

Auto-tiering structure

Up to 3 primary (media-based) tiers total, up to 2 SSD tiers (write- and read-intensive SSDs)

RAID tiering

Auto-provisions and dynamically restripes multiple RAID levels on the same tier; eliminates need to pre-allocate RAID groups

Tiering customizations

User-defined profiles, option to "pin" volumes to any tier or RAID level

RAID support

RAID 0, 1, 5, 6, RAID 10, and RAID 10 DM (Dual Mirror); any combination of RAID levels can exist in single array

Thin provisioning

Active by default on all volumes, operates at full performance across all features

Thin snapshots

Records changes only, snapshots auto-migrate to lower-cost storage

Intelligent deduplication and compression

Compression only, selectable option per volume

Data Mobility and Migration Replication

Heterogeneous arrays (SC Series any-to-any)
Synchronous/Asynchronous via FC or iSCSI
Target/source relationships may be one-to-many or many-to-one
Supports all SC data services on source and target volumes
Change replication types and topologies on demand
Supports cross-platform replication with PS Series/EqualLogic arrays (either direction)

Volume mobility

Live Migrate (included in base product) enables host-transparent data movement among arrays; see also Federation section

Federated multi-array systems¾

Live Migrate (included in base product) enables host-transparent movement of volumes among arrays
Snapshots maintained/preserved during migration**************

Thin Import

Space-efficient, non-disruptive data migration from PS Series (EqualLogic) and MD3 arrays

Thin Clones

Clone standalone volumes with zero duplication of data
Clones maintain independent snapshots and replication
Ideal for VDI, test/dev, other applications that require discrete instances of common data
More efficient than dedupe for database copies

Data Protection, Disaster Recovery, Security, Business continuity

Live Volume bi-directional auto-failover, auto-repair3
Heterogeneous arrays (SC Series any-to-any, except SCv2000)
Continuous operations, disaster recovery, disaster avoidance
Includes third-site (tertiary) replication options with Live Volume Managed Replication
Zero RTO/RPO with customizable site failover SLAs per volume
VMware Metro Stretch Cluster, VMware Site Recovery Manager support

Thin snapshots¾

Records changes only, snapshots auto-migrate to lower-cost storage

Replay Manager¾

Application-consistent snapshots in Microsoft, VMware, Oracle environments

Data-at-rest encryption

Supports self-encrypting drives (SEDs)
Full Disk Encryption (FCE) based on AES-256
Drives certified to FIPS 140-2 Level 2¾
Key Management Server (KMS) options available for FIPS 140-2 Level 1, 2 and 3

External key manager support

Gemalto's SafeNet KeySecure k460, SafeNet KeySecure k250, SafeNet KeySecure k150v
Thales EMS 200

Management

Management interface

Browser-based (HTML 5)
- CloudIQ (cloud-based storage monitoring and analytics)
- Unisphere for SC (single-array element manager, no software installation required)
- Unisphere Central for SC (multi-array management)

Client application
- Dell Storage Manager _ Advanced multi-array, multi-site and cross-platform (PS Series) management

Federation

Create large multi-array systems under unified management, with seamless workload migration between arrays via included Live Migrate feature. Add arrays non-disruptively, efficiently utilizing their combined capacity and performance. Volume Advisor monitors federated arrays to suggest optimal data placement and load balancing. Volume movement does not impact snapshots or replication data protection. Federate like or unlike arrays, all SC models supported.*************

Scripting support

Microsoft PowerShell API
RESTful API

Host OS support

Microsoft® Windows Server®, SLES, VMware®, Citrix® XenServer®, RedHat®

Third-party application integration

VMware, Microsoft, IBM, OpenStack, Symantec, CommVault, Foglight, Docker

Data-in-place upgrades

NA

Coexistence with PS Series arrays

Replication in either direction¾
Day-to-day management from a single interface
Thin import: space-efficient, non-disruptive data migration from PS Series arrays

Certifications

VMware vSphere Metro Storage Cluster, VMware SRM, Veritas Storage Foundations Suite, IBM VIOS Recognized, Oracle Validated Infrastructure (OVI); see Dell Storage Support Matrix for additional certifications and details

Reporting/alerts

Support assist (phone home), remote diagnostics and performance monitoring, automated alerts, reports and notifications, departmental chargeback

Workload management

QoS, VVOLs

Physical

Rack size

3U

Height

13.33 cm (5.25 inches)

Width

44.5 cm (17.52 inches)

Depth

78.5 cm (30.9 inches)

Weight at max configuration

24.22 kg (53.4 lb)

Weight empty

15.15 kg (33.4 lb)

Rack support

ReadyRails™ II static rails for tool-less mounting in 4-post racks with square or unthreaded round holes, or tooled mounting in 4-post threaded-hole racks

Power

Power/wattage

2 hot-swappable power supplies (1378W or 1485W options)

Maximum output power

1378W supply option: 1378 W
1485W supply option: 1485 W

Maximum input power

1378W supply option: 1584 W
1485W supply option: 1688 W

Maximum input current

1378W supply option: 16 A
1485W supply option: 8.8 A

Maximum inrush current

55A for 10 ms or less

Nominal input voltage operating range

1378W supply option: 100-240 VAC
1485W supply option: 200-240 VAC

Nominal input frequency

50/60 Hz

Thermal output/heat dissipation (maximum)

1378W option: 5,770 BTU per hour
1485 option: 5,760 BTU per hour
(all-in-one base appliance, no expansion enclosures)

Environmental Operating Conditions

Operating temperature

50 - 95°F (10 - 35°C)

Non-operating temperature

-40 - 149°F (-40 - 65°C)

Operating humidity ranges (non-condensing)

10% to 80% with 29°C (84.2°F) maximum dew point

Non-operating humidity (non-condensing)

5% to 95% with 33°C (91°F) maximum dew point

Inlet type

NEMA 5-15/CS22.2, n°42

Services, Warranties*******

Services

Dell ProSupport with deployment and consulting services. Optional ProSupport Plus is available offering proactive and preventative services to improve performance and stability. Dell Optimize is available for additional ongoing strategic counsel and guidance from a highly trained system analyst.

Diagnostics engine

Integrated Dell Remote Access Controller (iDRAC)

System sizing

Dell EMC Live Optics

Drive warranty

All SSDs are warrantied for full lifetime wear-out replacement with valid service agreement. SSD warranty covers all formats: SLC, MLC and TLC

* Net usable capacity of Dell array with 5 years of support, after 4:1 data reduction, vs. major competitors net of data reduction. Street price analysis is based on a variety of sources including analyst data, price sheets when available, and public information as of January 2017.

** Based on internal tests performed in February, 2018 on all-flash configurations. 100% sequential reads with 4K sector transfer size. Actual performance will vary based on configuration, usage and manufacturing variability. See Specifications section for additional Dell EMC performance test results.

*** Requires optional Live Volume feature

**** Based on internal tests in February 2018 on all-flash SC9000 configurations running 100% sequential reads. Tests covered 16Kb-2048Kb sector transfer sizes. Actual performance will vary based on model, configuration, usage and manufacturing variability.

***** Based on internal tests performed by Dell EMC on SCv3000 array with and without distributed sparing mode active. Actual performance will vary based on configuration, usage and manufacturing variability.

****** Ranking by vendor revenue. IDC Tracker, "Worldwide Quarterly Enterprise Storage Systems Tracker." 1Q17.

******* Availability and terms of Dell Services vary by region. Contact your Dell representative or Authorized Partner for details.

******** Contact your Dell EMC representative or Authorized Partner for details regarding the Future-Proof Storage Loyalty Program. Terms and Conditions apply.

********* Requires update to SCOS 7.3 for support. Subject to hardware availability (estimated Q218 for 25Gb, Q318 for 100Gb).

********** Based on internal tests performed in February 2018 on all-flash configurations running OLTP type workloads with 80% reads, 20% writes and 4k sector transfer size. Actual performance will vary based on configuration, usage and manufacturing variability.

*********** Based on internal tests in February 2018 on all-flash configurations running 100% sequential reads. Tests covered 16Kb-2048Kb sector transfer sizes for SC9000, and 256Kb-2048Kb sizes for SCv3000, SC5020 and SC7020. Actual performance will vary based on model, configuration, usage and manufacturing variability.

************ Based on internal tests in February 2018 on all-flash configurations running 100% sequential writes. Tests covered 64Kb-2048Kb sector transfer size for SC9000 and SC5020, 128Kb-2048Kb for SC7020, and 256Kb-2048Kb for SC7020. Actual performance will vary based on model, configuration, usage and manufacturing variability.

************* Multiple SC Series arrays may be deployed in federated configurations using the Live Migrate feature included with firmware version 7.1 and above. Transparent, non-disruptive volume movement among arrays is enabled, allowing the combined capacity and cache of the entire federated cluster to be seamlessly utilized for maximum performance and scalability in expanding data centers. For example, a cluster of 10 SC9000 arrays can provide a total of over 10,000 drives (up to 60PB raw capacity) with over 5TB of system memory.

************** Available Q218 for SC5020, Q318 for SC7020. Professional Services assistance required, subject to system eligibility requirements. Contact your Dell EMC representative or Authorized Partner for details.
Close

SCv300, SCv320, SCv360 expansion enclosures

Mix and match to grow your SCv3000 up to to 222 drives per array

Close

SCv300 expansion enclosure

  • Mix and match with other SCv3xx Series enclosures
  • Supports a variety of drive types including SAS, NL-SAS HDDs and SSDs
  • Redundant, hot-swappable power supplies
  • Cooling efficiencies lower power requirements and better protect your data
Feature Description
Form factor 2U
Drives 3.5” HDDs and 2.5" SSDs (with drive carriers)
Maximum drives per enclosure 12
Intermixed drive type support Yes
Close

SCv320 expansion enclosure

  • Mix and match with other SCv3xx Series enclosures
  • Supports a variety of drive types including SAS, NL-SAS HDDs and SSDs
  • Redundant, hot-swappable power supplies
  • Cooling efficiencies lower power requirements and better protect your data
Feature Description
Form factor 2U
Drives 2.5” HDDs and SSDs
Maximum drives per enclosure 24
Intermixed drive type support Yes
Close

SCv360 expansion enclosure

  • Ultra-dense storage option
  • Mix and match with other SCv3xx Series enclosures
  • Supports a variety of drive types including SAS, NL-SAS HDDs and SSDs
  • Redundant, hot-swappable power supplies
  • Cooling efficiencies lower power requirements and better protect your data
Feature Description
Form factor 4U
Drives 3.5” HDDs and 2.5" SSDs (with drive carriers)
Maximum drives per enclosure 60
Intermixed drive type support Yes
OK